- Technical Data
| PROPERTIES | METHOD | UNIT | VALUES |
MIN. TOLERANCES |
MAX. TOLERANCES |
| Lenght | TS EN 1842-2 | m | 50 | 0% | 4% |
| Width | TS EN 1842-2 | mm | 1500 | -0.50% | 1.50% |
| Mass per Unit Area | EN 1849-2 | gr/m² | 160 | -10 | 10 |
| Reaction to Fire Class | EN 13501 / EN 11925-2 | Class | E | - | - |
| Resistance to Water Penetration | EN 1928 Method A | Class | W1 | - | - |
| Water Vapor Transmission Properties (Sd) | EN 1931 | m | >10 | -0.01 | 20 |
| Tensile Properties: Maximum Tensile Force | EN 12311-2 / EN 13859-1B | N / 50mm | MD 520 / CD 515 | MD-40 / CD-30 | MD 55 / CD 45 |
| Elongation | EN 12311-2 / EN 13859-1B | % | MD 17 / CD 19 | MD-10 / CD-15 | MD 15 / CD 20 |
| Resistance to Tearing | EN 12310-1 / EN 13859-1A | N | MD 175 / CD 210 | MD-40 / CD-50 | MD 75 / CD 75 |
| Joint Strength | EN 12317-2 | N | MD 137 / CD 93 | MD-40 / CD-50 | MD 75 / CD 75 |